Products
- Other Audio & Video Equipments[2]
- Other Generators[1]
- General Assay & Diagnostic Apparatus[1]
- Counters[1]
- Clamp Meters[3]
- Multimeters[10]
- Other Electrical Instruments[1]
- Resistance Meters[2]
- Signal Generators[1]
- Other Measuring & Gauging Tools[5]
- Laser Rangefinders[1]
- Other Measuring & Analysing Instruments[4]
- Height Measuring Instruments[1]
- Temperature Instruments[3]
- Testing Equipment[4]
- Weighing Scales[1]
Contact Us
- Contact Person : Ms. Lin Monkey
- Company Name : Shenzhen Victor Hi-Tech Co., Ltd.
- Tel : 86-755-82426859,262
- Fax : 86-755-25921032
- Address : Guangdong,Shenzhen,2f, Block 12, Bagua 4rd. Futian Dist. Shenzhen City,Guangdong Province, China
- Country/Region : China
- Zip : 518029
Product Detailed
Related Categories:Other Measuring & Analysing Instruments
Related Product Searches:V/mA Calibrator,High Quality,V/mA Calibrator, Calibrator,VICTOR 15+
High Accuracy of 0.02% for measure and source.
5 digits display for measure, and 6 digits display for
source.A dual, Liquid
Related Product Searches:V/mA Calibrator,High Quality,V/mA Calibrator, Calibrator,VICTOR 15+
TECHNICAL DATA (Output Function)
Function | Reference | Range | Resolution | Accuracy | Remark |
DC voltage | 1000mV | -100.00∼1100.00mV | 10μV | 0.02+0.01 | Maximum output: 2mA |
10V | -1.0000∼11.0000V | 0.1mV | 0.02+0.01 | Maximum output: 5mA | |
DC current | 20mA | 0.000∼22.000mA | 1μA | 0.02+0.02 | Simulator transmitter: 528V power supply outside;1KΩ at 20mA |
FREQ | 100Hz | 1.00Hz∼110.00Hz | 0.01Hz | ±2 count | Output voltage: +1+11 V (zero base waveform);Amplitude accuracy: ±10%+0.5V;Maximum load: >100 KΩ;Duty Cycle: 50%. |
1KHz | 0.100KHz∼1.100KHz | 1Hz | |||
10KHz | 1.0KHz∼11.0KHz | 0.1KHz | |||
PULSE | 100Hz | 1∼100000cycles | 1cyc | ||
1KHz | |||||
10KHz | |||||
LOOP | 24V | ±10% | Maximum output current: 25 mAShort circuit protected |
Measuring Function | |||||
Function | Reference | Range | Resolution | Accuracy | Remark |
DCV | -20.00∼220.00mV | 10μV | 0.02+0.02 | -20.00∼220.00mV | Input Resistanceapproximately 100MΩInput Resistance approximately 1MΩ |
-0.5000∼5.5000V | 0.1mV | 0.02+0.01 | -0.5000∼5.5000V | ||
-5.000∼55.000V | 1mV | 0.03+0.01 | -5.000∼55.000V | ||
DCmA | 50mA | -4.000∼55.000mA | 1μA | 0.02+0.01 | Input Resistance5Ω |
FREQ | 500Hz | 3Hz∼500.00Hz | 0.01Hz | ±2count | Input Impedance100 kΩ at least;Sensitivity3Vp-p minimum;Duty Cycle: 50%. |
5KHz | 3Hz∼5.0000KHz | 0.1Hz | |||
50KHz | 3Hz∼50.000KHz | 1Hz | |||
CONTINUITY | ≤250Ω sound | CLOSE / OPEN | Open circuit voltage:about 2.5V | ||
PRESS | Defined by pressure module | Defined by pressure module | Defined by pressu-re module | For more detail, refer the pressure module about APM. |
General Characters | |
Power | 4×1.5AAA-size alkaline batteries (AC adapter can charge Ni-Hi battery) |
Max.allowable voltage | 30V |
Operation temperture range | 0-50°C |
Operation humidity range | ≤80%RH |
Store temperature range | ≤-10°C-55°C |
Store humidity range | ≤90%RH |
Size | 205×95×42mm |
Weight | 500g(with holster) |
Accessories | Test leads,Fuse |
Options | AC adapter(VCPS), |
Security | Conforms to IEC 1010 |
V/mA Calibrator